精品国产一区二区亚洲人成毛片_日韩视频在线观看免费_成年人一级黄色片_久久国产精品免费_国产一区二区三区精品视频_亚洲另类色综合网站_黄色美女网站在线观看

Chinese

Advisory hotline: 4008-557-528

hot key words: Dongguan skived fin heat sink vendor Shenzhen skived fin heat sink vendor Dongguan PV inverter heat sink PV inverter heat sink vendor Jiangsu skived fin heat sink vendor Custom SVG heat pipe thermal module

According to the national regulation on electrical grids, the portion of distributed power generation by PV and wind power should not exceed 10% of the electrical grid. An energy storage system is required if it exceeds this percentage. If there is no energy storage system in PV systems or wind power systems, it will result in adverse effects on the electrical grid. When the scale of the wind power systems or PV power generation systems keep increasing and the percentage of PV power within the systems keep increasing, these effects will become non-negligible. It is known from the analysis of characteristics of PV power generation that the influence of a PV generation system on the electrical grid is mainly due to the instability of PV powers. To ensure the safe, stable, and economical operation of electrical grids, typically it is required to install an energy storage system. As a result, the demands for energy storage systems have increased for the last couple of years.
The stable operation of an energy storage system is closely related to the safety and stability of the electrical grid. Therefore, every major energy storage system manufacturer emphasizes very much on the quality of their products. Among the factors that affect the stability of an energy storage system, the cooling performance is no doubt the most important one. Winshare Thermal has been focusing on the high power cooling techniques and has abundant experiences in the development and manufacturing of cooling solutions for energy storage systems. We are also capable of further optimizing the cooling performance of energy storage systems. Via abundant thermal design data that we have accumulated for years, Winshare Thermal can provide accurate thermal simulation and thermal management testing data.
Schematic of the simulation model for the inverter:
Schematic of the inverter module composition:
Schematic of the inverter module composition, heat-dissipating component distribution and relevant parameters:
Parameters of INV module:
IGBT:317.2W,no other additional heat consumption;
Thermal conductive interface:0.1MM,K=4W/m*K;
IGBT Rjc=0.74K/W,diode Rjc=0.84 K/W。

(Figure) Distribution ofRFC heat-dissipating components and IGBT power consumption parameters
 
Parameters of RFC module:
IGBT:223.8W,no other additional heat consumption;
Thermal conductive interface:0.1MM,K=4W/m*K;
IGBT Rjc=0.65K/W diode Rjc=0.86。

(Figure) Distribution ofRFC heat-dissipating components and IGBT power consumption parameters
 
Schematic of the fan used in simulation:
A Minebea06038DA-12R-EUD-1 15000RPM fan is used
Schematic of the placement of heat sinks for the inverters of the energy storage system in the simulation (see 3D model)
Schematic of the heat dissipation velocity of the heat sinks for the inverters of the energy storage system along a cross section:
Schematic of the vector dissipation of the heat sinks for the inverters of the energy storage system along a cross section:
 
Simulation results and schematic of the airflow vector dissipation:
Simulation results and schematic of temperature dissipation of the heat sinks for inverters:
 
Simulation results and schematic of temperature dissipation of the heat sinks for INV module:
Simulation results and schematic of temperature dissipation of the heat sinks for RFC module:
 
Summary of the simulation results on the heat sinks for inverters of energy storage systems:

Cooling solution

Heat sink
base temperature

Heat sink temperature
increase

Ambient temperature

IGBT   maximum case temperature and temperature differences(℃ 

INV

INV Temperature difference

RFC

RFCTemperature difference

Aluminum extrude heat sink

64.6

39.6

25

97.7

5.5

89.6

4.7

The thermal conductivity of the thermal interface material is assumed to be 4W/m*K.

The voice of Winshare Thermal: credit and word

Winshare Thermal Ltd. (hereinafter referred to as Winshare Thermal) was founded in 2009. We specialize in the research and development, production and technical services of high power cooling solutions. We are devoted to becoming the leader in the thermal... [See details]

Copyright: Dongguan Winshare Thermal Ltd.

主站蜘蛛池模板: 欧美日韩精品在线视频 | 韩国三级hd中文字幕有哪些 | 国产精选第一页 | 久久精品伊人波多野结 | 韩国三级久久 | 午夜免费观看福利片一区二区三区 | 天天曰夜夜曰 | jizz之18| 亚洲视频日韩视频 | 日本一区免费在线观看 | 欧美国产在线观看 | 国产精品一区二区久久 | 亚洲日韩欧洲无码av夜夜摸 | 亚洲欧美精品中字久久99 | 2018天天操天天干 | 日本三级s级在线播放 | 好看的三级 | 精品一卡2卡三卡4卡免费观看 | 久久99精品久久久久久青青91 | 天天做天天爱天天爽综合区 | 日本高清免费h色视频在线观看 | 国产盗摄一区二区 | 欧美高清69hd| 国产综合精品久久久久成人影 | 九九精品在线视频 | 91影视永久福利免费观看 | 亚洲天堂免费 | 日本三级香港三级三级人 | 国产又黄又爽视频免费观看 | 狠狠色噜噜狠狠狠狠米奇7777 | 日本三级欧美三级 | 久草免费福利资源 | 免费一级毛片在线播放 | 国产区欧美| 日韩在线免费看网站 | 天天干天天添 | 久久午夜一区二区 | 国产成人啪午夜精品网站 | 欧美手机在线 | 精品在线一区二区三区 | 国产精品亚洲专区在线播放 |